The use of failure assessment diagrams (FAD) for evaluating the integrity of components containing crack-like flaws has developed a well-defined methodology over the years that includes a correction factor to account for combined loading effects that are a result of primary and secondary stresses. The load combination factor, , is based on the Option 1 FAD currently in use in the Central Electricity Generating Board's (CEGB) report No. R/H/R6 (R6) and the API-579-1/ASME FFS-1 fitness-for-service standard. The factors for the Option 2 FAD based on ASME B factors based on the Option 1 FAD are recalculated here and compared to current published data. The approach utilizing Option 1 FAD methods is evaluated here with regard to its conservatism and applicability to material models other than the Ramberg-Osgood model. In addition, a sensitivity analysis is performed to estimate factor errors due to uncertainty in material property parameters. A critical review of the tabulated data in API-579 is performed and errors are identified along with suggested solutions to correct the data.
Product Details
Published: 2014 Number of Pages: 204 File Size: 1 file , 7.4 MB