Describes the basis of the liquid petroleum internal corrosion direct assessment (LP-ICDA) method and its four steps: (1) pre-assessment, (2) indirect assessment, (3) direct examination, and (4) post assessment. With the LP-ICDA approach, assessments can be performed on pipe segments for which alternative methods (e.g., in-line inspection, hydrostatic testing, etc.) may not be practical. This methodology may be incorporated into corrosion integrity and risk management plans.
Author | NACE |
---|---|
Editor | NACE |
Document type | Standard |
Format | File |
EAN ISBN | 1-57590-221-4 |
ICS | 77.060 : Corrosion of metals |
Number of pages | 35 |
Year | 2008 |
Document history | |
Country | USA |
Keyword | 0208;SP0208 |