Could I help you?
New Sale! View larger

IEEE 433-1974 [ Withdrawn ]

New product

IEEE 433-1974 [ Withdrawn ] IEEE Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low Frequency

standard by IEEE, 12/18/1974

More details

$56.32

-56%

$128.00

More info

Full Description

Scope

Design innovations and rating increases of rotating machines continuously increase the need to develop improvedmethods of testing insulation for serviceability. Research in the last 15 years evolved a method of 1/10 Hz overpotentialtesting to supplement traditional power-frequency testing and to complement direct-voltage testing. A background for VLF (very low frequency) testing is available in the technical literature. (See Section 11.) VLF testing permits advantageous application of more easily transportable equipment both in weight and size as compared to non-resonant power-frequency testing.This document provides a uniform method of VLF testing in order to obtain consistent results, accumulate meaningful experience, and lead to establishment of standards of test level.References as listed in Section 10. are necessarily those which have been issued at the time this document was written.When subsequent revisions of the references are issued, they should be used in place of those indicated unless, due to a change in scope, they no longer apply.

Purpose

The purposes of this recommended practice are:1) To de ne terms that have a speci c meaning in VLF testing2) To describe VLF-test equipment and wave shape3) To provide a uniform procedure for testing the armature insulation of large ac machines with VLF voltage4) To recommend constants for relating VLF tests to power-frequency and direct-voltage tests to obtain equally effective test levels.This document applies to large ac rotating machines rated at 10 000 kVA or greater and rated 6000 V or higher. It covers acceptance testing of new equipment in the factory or on-site after erection. This recommended practice also covers routine maintenance testing of machines that have been in service.

Abstract

New IEEE Standard - Inactive-Withdrawn.Terms that have a specific meaning in VLF testing are defined, and VLF test equipment and wave shape are described. A uniform procedure for testing the armature insulation of large AC machines with VLF voltage is provided. Constants for relating VLF tests to power-frequency and direct-voltage tests to obtain equally effective test levels are recommended.

Product Details

Published: 12/18/1974 ISBN(s): 0738107719, 9780738139623 Number of Pages: 15File Size: 1 file , 160 KB Product Code(s): STDWD4333