Could I help you?
New Sale! View larger

IEEE C63.19-2007

New product

IEEE C63.19-2007 American National Standard Methods of Measurement for Hearing Aid Compatibility with Wireless Communications

standard by IEEE, 06/08/2007

More details

$54.12

-56%

$123.00

More info

Full Description

Scope

This standard applies to both wireless communications devices (WDs) and hearing aids. It sets forthuniform methods of measurement and parametric requirements for the electromagnetic and operationalcompatibility and accessibility of hearing aids used with WDs, including cordless, cellular, personal communications service (PCS) phones, and voice over internet protocol (VoIP) devices, operating in the range of 800 MHz to 3 GHz. However, this version is focused on existing services, which are in common use. Accordingly, in this version tests are provided for services in the 800 MHz to 950 MHz and 1.6 GHz to 2.5 GHz frequency bands. Future versions may add tests for other frequency bands, as they come into more common use.This standard is intended to apply to all types of hearing aids with acoustic output, including, as examples, behind-the-ear (BTE), in-the-ear (ITE), in-the-canal (ITC), and completely-in-the-canal (CIC) types. Test methods are provided for hearing aids operating in acoustic (microphone input) mode or in tele-coil (T-Coil) input mode.The field levels called for in various places shall be maintained within the limits for radio frequency (RF) safety, set forth in IEEE Std C95.1.11 For information on references, see Clause 2.1

Purpose

The purpose of this standard is to establish categories for hearing aids and for WDs that can indicate to healthcare practitioners and hearing aid users which hearing aids are compatible with which WDs and to provide tests that can be used to assess the electromagnetic characteristics of hearing aids and WDs and assign them to these categories. The various parameters required, in order to demonstrate compatibility and accessibility are measured. The design of the standard is such that when a hearing aid and WD achieve one of the categories specified, as measured by the methodology of this standard, the indicated performance is realized.In order to provide for the usability of a hearing aid with a WD, several factors must be coordinated as follows: RF measurements of the near-field electric (E) and magnetic (H) fields emitted by a WD tocategorize these emissions for correlation with the RF immunity of a hearing aid H-field measurements of a WD emitted via the audio transducer associated with the T-Coilmode of the hearing aid, for assessment of hearing aid performance Measurements with the hearing aid and a simulation of the categorized WD T-Coil emissions toassess the hearing aid RF immunity in the T-Coil modeThe WD s RF and audio band emissions are measured. Hence, the following are measurements made forthe WDs:1) RF E-field emissions2) RF H-field emissions3) T-Coil mode, magnetic signal strength in the audio band4) T-Coil mode, magnetic signal and noise articulation index5) T-Coil mode, magnetic signal frequency response through the audio bandCorresponding to these quantities, the hearing aid is measured for the following:a) RF immunity in microphone modeb) RF immunity in T-Coil modeThe hearing aid T-Coil reception characteristics are also important when assuring the usability of the T-Coil mode. When these characteristics are coordinated, the goals of compatibility and accessibility are accomplished.Two principal conditions expose hearing aid equipped users to undesired RF electromagnetic disturbances. The far-field condition corresponds to the type of field a hearing aid equipped bystander would experience when adjacent to a WD user. The near-field condition corresponds to the more intense fields that a hearing aid equipped user of a WD would experience. This standard assesses the near-field or user condition.This standard describes preferred test methods and test facilities and, in some cases, alternative test methods and facilities. If alternative test methods or facilities are employed, every effort shall be made to establish correlation with the preferred ones. Any deviation from the preferred test methods, as set forth in this standard, shall be fully described in the test report.2Wherever the word shall is used in this standard, it indicates something mandatory. The word shouldindicates something that is advisory. The word may indicates an option, which is at the discretion of the test engineer.

Abstract

New IEEE Standard - Active.Uniform methods of measurement for compatibility between hearing aids and wireless communications devices are set forth.

Product Details

Published: 06/08/2007 ISBN(s): 9780738156149, 978073810000 Number of Pages: 141File Size: 1 file , 3.7 MBRedline File Size:3files, 13 MB Product Code(s): STDSURL95692, STDSU95692