Could I help you?
New Sale! View larger

IEEE 1835-2014

New product

IEEE 1835-2014 NACE International and IEEE Joint Standard Practice for Atmospheric (Above Grade) Corrosion Control of Existing Electric Transmission, Distribution, and Substation Structures by Coating Systems

standard by IEEE, 05/01/2015

More details

$21.12

-56%

$48.00

More info

Full Description

Scope

This standard provides a procedure that shall be used to (1) assess structures for atmospheric corrosion; (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system; (3) make informed decisions based on those findings as to whether coating repair is needed, and if so, to what extent; and (4) apply repair coatings to the structure if applicable. This standard applies to the repair of above-grade atmospheric coatings. For the purposes of this standard, the atmospheric area to be coated generally comprises of that portion of the utility support structure above the transition zone, which is that portion of the coating exposed up to 600 mm (24 in) above grade.

Purpose

This standard serves as a resource for preparing specifications to achieve the successful coating of utility structures.

Abstract

New IEEE Standard - Active.This standard provides a procedure that shall be used to (1) assess structures for atmospheric corrosion; (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system; (3) make informed decisions based on those findings as to whether coating repair is needed and if so, to what extent; and (4) apply repair coatings to the structure if applicable. This standard applies to the repair of above-grade atmospheric coatings. For the purposes of this standard, the atmospheric area to be coated is generally comprised of that portion of the utility support structure above the transition zone. This standard is limited to the above-grade and atmospheric portions of utility support structures. It does not address below-grade coating repair within and below the transition zone. This standard does not address foundations or guy anchoring systems. This standard does not cover the coating of aluminum, weathering steel, concrete, or any material other than steel. Likewise, it does not cover the coating of non-support structures such as fencing, buildings, transformers, or other miscellaneous components within the transmission, distribution, and substation systems. This standard does not cover new construction, transition zone, below-grade, or water immersion. These areas of concern are addressed specifically in other NACE/IEEE standards. This standard does not address mechanical or structural damage, mechanical or structural repairs, or structural integrity.

Product Details

Published: 05/01/2015 ISBN(s): 9780738194462, 9780738194479, 9781504416917 Number of Pages: 20File Size: 1 file , 290 KB Product Code(s): STD20051, STDPD20051, STDPL20051