Could I help you?
New Reduced price! 2926 -- Thermal Effect on Pressure Distribution in Simulated High-Rise Buildings: Experiment and Analysis View larger

2926 -- Thermal Effect on Pressure Distribution in Simulated High-Rise Buildings: Experiment and Analysis

M00004046

New product

2926 -- Thermal Effect on Pressure Distribution in Simulated High-Rise Buildings: Experiment and Analysis

Conference Proceeding by ASHRAE, 1985

K.H. Lee; Y. Lee, Ph.D.; H. Tanaka, Ph.D.

More details

In stock

$6.60

-56%

$15.00

More info

Full Description

A study has been made, both experimentally and analytically, on the characteristics of thermal performance of high-rise buildings using an idealized model building with a number of openings at various locations and temperature distributions. The building was assumed to have no internal partitions. The effect of the factors affecting on the location of the neutral pressure level (NPL) was of particular interest of the present study.

Units: SI

Citation: ASHRAE Transactions, 1985, vol. 91, pt. 2A, Honolulu, HI